Sensors | ||||
Unit | Range | Resolution | Accuracy | |
Carbon Dioxide (CO₂) |
ppm | 400 to 10,000 ppm |
1 ppm |
±50 ppm plus ±3% of actual value |
Dust (PM2.5) |
µg/m3 |
1 to 200 µg/m3 |
1 µg/m3 |
±15 µg/m3 or ±10% of actual value* |
Nitrogen Dioxide (NO₂) |
ppb |
1 to 1,000 ppb |
1 ppb |
±20 ppb or ±10% of actual value* |
Relative Humidity |
% | 0 to 100% |
0.1% |
±3%
|
Air Pressure |
hPa |
300 to 1,100 hPa |
0.1 hPa |
±1 hPa |
Carbon Monoxide (CO) |
ppm | 0 to 1,000 ppm |
0.1 ppm |
±2 ppm or ±5% of actual value* |
Temperature | °C |
-40 to 85 °C |
0.1 °C |
±0.5 °C |
Airborne Chemicals (VOCs) |
ppb | 0 to 30,000 ppb |
1 ppb |
±20 ppb or ±15% of actual value* |
Ozone (O₃) |
ppb | 1 to 1,000 ppb |
1 ppb |
±20 ppb or ±10% of actual value* |
Special Features | Smart Control, Virus Index Monitoring |
Filter Type | VOC |
Capacity | 0.5 litres |
Operation Mode | automatic |
Room Type | Office, Bedroom |
Power Source Type | Corded Electric |
Control Method | App |